Resistance thermometers

Resistance thermometers with Pt100/Pt1000 resistance

Resistance thermometers are equipped with platinum sensor elements which change their electrical resistance as a function of temperature. In our range of products you will find resistance thermometers with connected cable as well as versions with connection head. A temperature transmitter can be installed directly in the connection head. Resistance thermometers are suitable for applications between -200 ... +600 °C (dependent on instrument model, sensor element, accuracy class and materials coming into contact with the medium). Accuracy classes AA, A and B apply to all resistance thermometers. They are available with a tolerance value to IEC 60751.

Sales contact

WIKA Croatia d.o.o.

Tel.:
+385 1 6531-034
Fax:
+385 1 6531-357
info@wika.hr

FAQ

How large is the measuring error caused by the internal lead resistance with a Pt100 built into an MI cable with Cu internal wires in a 2-wire connection?

D=3 mm : 0.28 Ohm/m = 0.7 K/m (measuring error)
D=6 mm : 0.1 Ohm/m = 0.25 K/m (measuring error)
(D=external diameter of the MI cable)

What does "positive temperature coefficient thermistor" mean?

Positive temperature coefficient thermistors conduct electricity worse at higher temperatures than at lower temperatures. They are also known as PTC resistances (Positive Temperature Coefficient). Typically PTC are used in high-value temperature measuring points, e ... More

Wish list - Documents (0)

There are currently no documents on your wish list. You can add any document from the download area to your wish list. To do this, select the desired language using the flag symbol.

The maximum number of 20 entries was reached.

To receive your download link via e-mail, enter your address here:

The e-mail address is invalid.